DAWEI Intelligent Equipment Co., Ltd
HOME    Musashi Dispenser  MUSASHI DISPENSER  Air Pulse Method
Full Function Digital Control Dispenser SuperΣCMⅣ Pro
DAWEI Intelligent Equipment Co., Ltd

musashi dispenser SuperΣCMⅣ Pro

Pursue the ultimate productivity

Equipped with independent AIR OUT unit and temperature controller.

In addition to traditional features, ΣCMIV is even more powerful!

Point

■The independent AIR OUT unit maintains the highest discharge responsiveness and discharge accuracy even in long piping environments!

■Equipped with a temperature controller. Since both heating and cooling of the syringe can be performed, fluctuations in the amount of application due to rising liquid temperature can be suppressed.

Outline Specification ( musashi dispenser SuperΣCMⅣ Pro )

Name

Full-function digital control Musashhi Dispenser SuperΣCMIV Pro

ModelS-SIGMA-CM4P -CTR-V7-NS-SIGMA-CM4P -CTR-V7-PS-SIGMA-CM4P -CTR-V2-NS-SIGMA-CM4P -CTR-V2-PS-SIGMA-CM4P -CTR-V05-NS-SIGMA-CM4P -CTR-V05-P
Spill pressure setting range When Σ function is ON30.0 ~ 700.0 [kPa]20.0 ~ 200.0 [kPa]5.0 ~ 50.0 [kPa]

Spill pressure setting range When Σ function is OFF

20.0 ~ 700.0 [kPa]5.0 ~ 200.0 [kPa]0.5 ~ 50.0 [kPa]
Output time setting range When Σ function is ONTimed mode: 0.020 to 9999.999[s] (depending on tube length)

Manual mode: 0.035 ~ 9999.999 [s]

Output time setting range

When Σ function is OFF

0.001 ~ 9999.999 [s]
Discharge modeTimed mode, manual mode
Vacuum pressure setting range0.00~ -5.00 [kPa]
Main Functions

Automatic waterhead difference correction, automatic liquid leakage prevention, automatic residual volume warning, alpha correction, delta correction, residual volume display correction, vacuum pressure correction, discharge counter, stopwatch, interval discharge, discharge condition correction, autoclear, autoclear, autoclear, express shot, date and time, operation history, discharge pressure monitoring, self-diagnosis, ECO mode (*), sleep mode, I/O function allocation, password lock, display unit switching (kPa/bar), solenoid valve error, air pressure error, vacuum pressure error, copy, auto tuning, auto tuning

Signal specificationNPNPNPNPNPNPNPNPNP
Number of channels400CH


※ S-SIGMA-CM4P-CTR-V05-(N/P) does not support ECO mode (equivalent to ECO mode OFF).

musashi dispenser SuperΣCMⅣ Pro

*
*
*
*
FDW(DAWEI)
No. 719-720, 7th floor, Thanh Dat 1 Building, No. 3 Le Thanh Tong Street, May To Ward, Ngo Quyen Dis
 
Tầng 6 Tòa nhà Dương Tuấn, P Võ cường, TP Bắc Ninh
武孟想 (Giám Đốc Kinh Doanh)
MST: 0201931305
Mobile: 0978 650 432
Email: wmx@vnfdw.com
三浦 裕一 (SALES ENGINEER)
TAX ID: 0105553096889
TEL: (66)02022 9015-16
FAX: (66)02 769 5450)
HP: (66)095 562 6968
E-mail: miura@musashi-engineering.co.th